Contact Products
Handheld radios Commercial radios Mobile & repeater Accessories
Knowledge Base About Service
Get a quote

Sales hotline 400-800-2026

Product Guides

What Ex ib IIC T4 Gb actually means on a radio

The certificate label is not decoration. Each part of that string describes a different limit, and procurement teams are right to ask about it.

Reading the marking

  • Ex — equipment certified for explosive atmospheres
  • ib — intrinsic safety level b: safe with up to two faults
  • IIC — gas group IIC, the most demanding group (hydrogen, acetylene)
  • T4 — surface temperature class, maximum 135 °C
  • Gb — equipment protection level for Zone 1

Why intrinsic safety, not just "rugged"

An ordinary radio can arc when transmitting or when a battery shorts. In a Zone 1 area, that spark is enough. Intrinsically safe design limits the energy in the circuit so no spark and no hot surface can occur, even under fault conditions.

What to ask a supplier

Ask for the certificate number, the issuing body, and whether the battery is covered by the same certificate. A radio with an IS body and a non-IS battery is not IS.

Using it correctly

IS protection holds only with the certified battery, original accessories and intact housing. Dropping a radio and cracking the case voids the protection until it is repaired by an approved centre.

Last updated 2026-11-26

Get a quote