Reading the marking
- Ex — equipment certified for explosive atmospheres
- ib — intrinsic safety level b: safe with up to two faults
- IIC — gas group IIC, the most demanding group (hydrogen, acetylene)
- T4 — surface temperature class, maximum 135 °C
- Gb — equipment protection level for Zone 1
Why intrinsic safety, not just "rugged"
An ordinary radio can arc when transmitting or when a battery shorts. In a Zone 1 area, that spark is enough. Intrinsically safe design limits the energy in the circuit so no spark and no hot surface can occur, even under fault conditions.
What to ask a supplier
Ask for the certificate number, the issuing body, and whether the battery is covered by the same certificate. A radio with an IS body and a non-IS battery is not IS.
Using it correctly
IS protection holds only with the certified battery, original accessories and intact housing. Dropping a radio and cracking the case voids the protection until it is repaired by an approved centre.
Last updated 2026-11-26